    內蒙古某鋼鐵集團780㎡球团电除尘器升级改造

    ● 配置1台780㎡四室四电场电除尘器,设计处理工况烟气量1282800m3/h;
    ● 电除尘器供电装置为一、二电场高频电源1.6A/80KV,三四、电场单相工频电源1.6A/80KV;
    ● 改造前电除尘器出口粉尘排放浓度150-200mg/Nm3。

    本體檢修主要內容:

    ● 优化气流分配,重新设计更换了气流分布孔板;
    ● 更换了受损的瓷瓶、阴极瓷转轴等绝缘件;
    ● 电场内部进行喷砂清灰、更换受损的阴极线,调整极距等检修工作;
    ● 增加了热风吹扫系统;

    電氣改造內容:

    ● 将三、四电场工频电源控制柜改造为智能变频脉冲电源控制柜;
    ● 整流变压器、隔离开关柜和供电电缆利旧;
    ● 低压控制柜利旧,优化控制程序;
    ● 新增上位机系统,实现对高低压电源参数监控显示。

    ● 15天内完成了电除尘器检修和电源改造工作;
    ● 升级改造后电除尘器出口粉尘排放浓度20mg/Nm3左右。